SPEED™ LD-1100 Recorder
The LD-1100 Field Recorder
collects data at the electric revenue meter location. Periodically this data is uploaded
for processing using Enetics' SPEED™ algorithm, which produces energy consumption
interval data for each major appliance in the residence.
The recorder is installed between the meter socket and the revenue meter on a
standard form 2S meter base. Installation also typically involves connection to the
phone line (if present) at the site. Typically, the unit shares the premises phone line
for periodic uploading of data and recorder management ("walk-up" data
collection methods are also available). The LD-1100 is configured for single and 2-phase
residential services.
The recorder samples the power line and computes watt and VAR values. It senses
transitions in these parameters and uses this information to determine exactly when a
particular appliance turns on or off. It then records, calculates and stores the date
and time of each on/off event along with the voltage, real and reactive power (watt,
VAR). The recorder also computes and stores the whole-building watt-hour and VAR-hours
for each recording interval. The recorder can also log internal temperature if the
Plug-in Temperature Sensor is in use at the premises.
Key Features
- Installation Ease - Installs in less that 15 minutes
- Rated for 200A direct metered service
- Records whole house energy consumption by interval
- Records edge data for appliance consumption analysis.
- Built-in phone modem
- Data transfer to Master Station via phone or
walk-up
Specifications
Form: 2S
Channels:
Voltage 2
Current 2
Range:
Voltage - 208/240
Current Form 2S (200A)
Memory
Non-volatile 2MB.
Sample Rate/Response Time:
32 samples/cycle
Accuracy:
Voltage - +/- 0.2% reading + 0.1% FS
Current - +/- 0.2% reading + 0.2% FS
Power - +/- 0.5% reading + 0.01% FS
Response Time/Recording Interval
Response Time: 20 cycles
Recording Interval: 1 min to 8 hour (Wraparound)
Communications:
Internal Modem Data Rate: 2.4 kbps
Serial Port: 19.2 kbps
Power:
From line voltage
Environmental/Physical:
Operating Temp Range: -20 oC to +70 oC
|